医療機器学
Online ISSN : 1884-054X
Print ISSN : 1882-4978
ISSN-L : 1882-4978
原  著
2種類の包装材料を使用した低温蒸気ホルムアルデヒド(LTSF)滅菌における被滅菌物へのホルムアルデヒド残留性の検討
久保田 英雄橋本 素乃津嘉山 身衣子田中 直文
著者情報
ジャーナル フリー

2018 年 88 巻 6 号 p. 613-619

詳細
抄録

Five types of reference test loads specified in EN14180 placed in a sterilizing bag or a sterilizing container were subjected to low temperature steam formaldehyde (LTSF) sterilization, and residual formaldehyde levels on the sterilized materials were measured. The result demonstrated that, regardless of which packaging material was used, formaldehyde levels on the sterilized materials were much lower than the reference value described in EN14180, suggesting that formaldehyde can be adequately removed by steam wash. It was suggested that low residual formaldehyde levels and safe operation can be achieved for various materials through appropriate sterilization process.