除塵機導入による調剤室内塵埃数の変化
林 弘祐秋田 昌宏近藤 源作須原 清治
著者情報
ジャーナル フリー

6 巻 (1980-1981) 3 号 p. 220-226

詳細
PDFをダウンロード (1024K) 発行機関連絡先
抄録

Dust particles in hospital pharmacy were reduced to 1/10 to 1/50 by an electric vacuum cleaner placed near the source of dust. The dust removal rate in the area away from the cleaner was lower: 1/3 to 1/15. Dust particles produced in drug dispensing consisted of relatively large ones (1.0-5.0μm in diameter), and most of those due to other factors such as smoking and working personnel were smaller (0.3-0.5μm). Consequently, the ratio of large dust particles of 1.0-5.0μm was higher in pharmacy than in other places, and the ratio of small ones of 0.3-0.5 μm was not so higher. When the vacuum cleaner was placed near the source of dust, most of the large particles over 1.0-5.0μm were removed. Consequently, the particles of this size were reduced in any part of pharmacy. However, smaller particles of 0.3-0.5μm were not efficiently removed in the area distant from the cleaner: particles left unremoved in such area were 3 to 6 folds as many as in the place around the cleaner.