前歯部仮想歯冠軸の設定に関する研究 (第1報)
佐々川 毅小見山 信山下 正博松本 幸士鳥塚 周孝桟 淑行斉藤 暁五十嵐 孝義
著者情報
ジャーナル フリー

33 巻 (1989) 6 号 p. 1433-1441

詳細
PDFをダウンロード (2161K) 発行機関連絡先
抄録

1. The state of inclination and the change under various conditions of the imaginary axis of the tooth crown of upper jaw anterior teeth can be determined by the image measuring system and method of this study.
2. The measurement error of this system was not more than 0.3 degree. This value was sufficient for the purpose of this study.
3. The imaginary axis of the tooth crown of anterior teeth was determined on the study cast with 1 to 3 degree in mesiodistal direction and 2 to 4 degree in labiopalatal direction as standard deviation.
4. The imaginary axis of the tooth crown of anterior teeth was determined toward labial in the random position and toward patient's right and palatal in Standing Posture.
5. It was confirmed that the determination of the imaginary axis of tooth crown was effected by the position of the patient relative to the operator, limitation or direction of view, and approach direction.