Japanese Journal of Radiological Technology
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
THE MEASUREMENT OF INTENSIETY OF SAFETY LIGHT LAMP
SENICHI TAKEYOSHI
Author information
JOURNAL FREE ACCESS

1962 Volume 18 Issue 3 Pages 204-208

Details
Abstract

There have been few reports on the measurement of the safe light lamp in a dark room. Therefore, the author made a few experiments to study this measurement. It was concluded that the intensity of the safe lamp in a room 3.3 m in area, was about 11.5 lux. Other experiments with films were conducted to determine the relation of film and developer to fog, and a simple method was worked out to change the intensity of a safety lamp.

Content from these authors
© 1962 Japanese Society of Radiological Technology
Previous article Next article
feedback