日本放射線技術学会雑誌
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
X線写真の汚染防止に関する研究(第1報)
佐々木 仙悦
著者情報
ジャーナル フリー

1974 年 29 巻 6 号 p. 470-475

詳細
抄録

Contamination of X-ray film is difficult to avoid when the bulk film processing is carried out by an automatic film processor. Developer in the processor frequently becomes discoloured due to oxidization of the primary developing chemical exacerbated by deletion of the sulfite caused by high temperature treatment. The developing rollers also become discoloured and contaminated while functioning in developer discoloured by oxidization. X-ray films become badly contaminated by the interaction of these two factors in the following manner, that is, oxides and silver chloride produced in developer adher to the film surface and dirt on the developing roller transfers to the film surface. We have developed a new developer resistent to discolouration through oxidation, and which also functions to maintain the clarity of radiographic image, and have made many test runs using in the automatic film processor and have had very satisfactory results.

著者関連情報
© 1974 公益社団法人 日本放射線技術学会