1991 Volume 47 Issue 11 Pages 1937-1942
We investigated the influence of observation time and viewing distance in ROC rating with simple signal patterns. We measured ROC curve varying observation time and viewing distance with the same sample film sets and same observation environments. To control these factors correctly, we made special observation equipment. When the observation time was varied, 5, 10 sec and free, there was no significant difference for visual detection performance. When viewing distance was varied, 50cm and free, there was no significant difference for visual detection performance.