日本放射線技術学会雑誌
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
非対称性増感紙・フィルム系の画像評価の理論的考察
若松 孝司岡田 弘治
著者情報
ジャーナル フリー

1994 年 50 巻 3 号 p. 371-378

詳細
抄録
A theoritical investigation of the image quality evaluation of asymmetric screen-film systems is developed. In connecting with the front and back side image of a film, it is helpful to assess the image quality by keeping in mind that an asymmetric screen-film system involves radiographic density rather than optical illuminance. Therefore, overall MTF depends on radiographic density comprising parallel linkage of each side MTF with relative gradient weight of an asymmetric screen-film system. Slit and chart measurement methods of MTF for asymmetric system are discussed. Consequently, it can successfully be to evaluate the image quality of the simulated asymmetric system by NEQ (u).