日本放射線技術学会雑誌
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
ノート
頭頸部領域におけるDeformable Image Registration Softwareを用いた自動輪郭抽出の臨床的評価
佐々木 幹治富永 正英加茂前 健生島 仁史岸 太郎川下 徹也多田 章久重光 翠笈田 将皇
著者情報
ジャーナル フリー

2013 年 69 巻 11 号 p. 1250-1260

詳細
抄録

The purpose of this study was to clinically evaluate the automatic outline extraction properties using general-purpose deformable image registration (DIR) software for the head and neck region. To this end, we evaluated the following: (1) the difference between manual outline extraction carried out by a radiation therapy specialist and automatic outline extraction using the DIR software, and (2) the precision of the automatic outline extraction for the diachronic figure change and change in the organ shape. The manually-extracted outline and that extracted using the DIR software closely resembled each other at 0.70. Further, in the same case, the automatic outline extraction precision of the DIR software was greater at about 0.80. Our findings suggest DIR software to be useful for lessening the work involved in outline extraction.

著者関連情報
© 2013 公益社団法人 日本放射線技術学会
前の記事 次の記事
feedback
Top