2025 年 73 巻 5 号 p. 198-208
Activities for improvement of force measurement accuracy have been carried out in wind tunnels of the Japan Aerospace Exploration Agency (JAXA) for about two decades. For the high accuracy of force balance measurement, several balances have been designed by the JAXA original simple method and calibrated using the JAXA automatic balance calibration machine, which was built in 2010. Many efforts have been made to the calibration machine, improving the repeatability of calibration and optimizing load patterns. In parallel, a balance with small hysteresis has been developed, and the double standard deviation of the residual error for 6-component combined-load random patterns is achieved to be 0.05% or less of full-scale load in the axial force component. This result is expected to significantly reduce errors in wind tunnel testing. Furthermore, the accuracy is clarified with and without combined load calibration, and guidelines for balance calibration corresponding to the purpose of various wind tunnel tests are discussed.