The Journal of Medical Investigation
Online ISSN : 1349-6867
Print ISSN : 1343-1420
Originals
Diagnosis of the presence of lymph node metastasis and decision of operative indication using fluorodeoxyglucose-positron emission tomography and computed tomography in patients with primary lung cancer
Hiroaki TobaKazuya KondoHideki OtsukaHiromitsu TakizawaKoichiro KenzakiShoji SakiyamaAkira Tangoku
Author information
JOURNALS FREE ACCESS

Volume 57 (2010) Issue 3,4 Pages 305-313

Details
Download PDF (669K) Contact us
Abstract

Objectives: We evaluate whether integrated fluorodeoxyglucose-positron emission tomography and computed tomography (FDG-PET/CT) scan can diagnose the presence of lymph node metastasis more accurately than computed tomography (CT) scan alone. Methods: Forty-two patients with lung cancer preoperatively underwent integrated PET/CT scan using FDG and CT scan and underwent pulmonary resection and lymph node dissection. We judged cases as lymph node metastasis if the lymph node visually accumulated FDG at PET/CT scan and measured 1 cm or greater in the short axis at CT scan. We retrospectively analyzed whether our judgments in each modality were consistent with the pathological diagnosis. Results: Two-hundred and seventeen stations of lymph node were dissected and 21 stations (9.7%) were histologically diagnosed as positive metastasis. Thirty-two stations of lymph node visually accumulated FDG at PET/CT scan and 17 stations measured 1 cm or greater in the short axis at CT scan. Concerning the diagnosis of lymph node metastasis, PET/CT scan showed significantly higher sensitivity than CT scan (81% vs. 48%, p=0.024). The false-positive rate was significantly high in PET-positive lymph nodes measuring less than 1 cm in diameter. There were 4 false-negative lymph nodes with both scans. All of these were less than 7 mm in diameter and had a low percentage of metastatic foci in the lymph node. Concerning the diagnosis of N staging, there was no significant difference between PET/CT scan and CT scan (83% vs. 69%, p=0.124). However, the identification of N2 disease at PET/CT scan was significantly more accurate than that at CT scan (100% vs. 38%, p=0.031). Conclusions: PET/CT is superior to CT scan in lymph node staging. However, because the false-positive rate is high in PET-positive lymph nodes measuring less than 1 cm in diameter, we think that clinical background should be considered and other modalities or histological examinations should be undertaken if necessary. J. Med. Invest. 57: 305-313, August, 2010

Information related to the author
© 2010 by The University of Tokushima Faculty of Medicine
Previous article Next article

Altmetrics
Recently visited articles
feedback
Top