Journal of Nippon Medical School
Online ISSN : 1347-3409
Print ISSN : 1345-4676
ISSN-L : 1345-4676
Originals
Usefulness of a Semicircular Capsulotomy Marker
Hisaharu SuzukiToshihiko ShiwaHideaki OharazawaHiroshi Takahashi
著者情報
ジャーナル フリー

2012 年 79 巻 3 号 p. 195-197

詳細
抄録

Purpose: To evaluate usefulness of a new semicircular capsulotomy marker in continuous curvilinear capsulorrhexis (CCC).
Methods: In 20 eyes of 20 patients who underwent cataract surgery, a newly designed semicircular marker with an internal diameter of 5.5 mm was used to place a circular mark directly on the lens capsule. The mark was then used as a guide to complete CCC of the set diameter. The resultant size of CCC in each case was confirmed by analysis of the video image.
Results: The average CCC diameter size was 5.2 ± 0.3 mm. In all cases, the edge of the intraocular lens was completely covered by the anterior capsule.
Conclusion: The semicircular capsulotomy diameter marker was useful in making a complete CCC of a set diameter.

著者関連情報
© 2012 by the Medical Association of Nippon Medical School
前の記事 次の記事
feedback
Top