Journal of Nuclear Science and Technology
Online ISSN : 1881-1248
Print ISSN : 0022-3131
Evaluation of Response of Whole-body Counter using the EGS4 Code
Sakae KINASE
Author information
JOURNAL FREE ACCESS

1998 Volume 35 Issue 12 Pages 958-962

Details
Abstract

Responses of a whole-body counter to distribution of ingested 137Cs within the body were evaluated using Monte Carlo simulation. The uncertainties in evaluation of 137Cs body burdens due to counting efficiencies of the whole-body counter were estimated. It was found from calculation that counting efficiencies of the whole-body counter are largely dependent on the 137Cs distribution within the body, and 137Cs body burdens would be underestimated by a factor of 3 in the worst case.
To testify a calibration method for the whole-body counter using Monte Carlo simulation, counting efficiencies for simple-geometric-form models and phantoms were obtained by simulation and actual measurements. The calculations by Monte Carlo simulation are in good agreement with the measurements.

Content from these authors

This article cannot obtain the latest cited-by information.

© the Atomic Energy Society of Japan
Previous article Next article
feedback
Top