Studies on the consistency of internally taken contrast medium for Pancreas CT
Kishio MATSUSHIMASeiichi MIMURASeiji TAHARATakuichi KITAYAMAKeiji INAMURAYasutaka MIKAMIKeiji HASHIMOTOYoshio HIRAKIKaname AONO
Author information
Keywords: Pancreas CT
JOURNAL FREE ACCESS

1985 Volume 97 Issue 1-2 Pages 47-53

Details
Abstract
A problem of Pancreatic CT scanning is the discrimination between the pancreas and the adjacent gastrointestinal tract. Generally we administer a dilution of gastrografin internally to make the discrimination. The degree of dilution has been decided by experience at each hospital.
When the consistency of the contrast medium is low in density, an enhancement effect cannot be expected, but when the consistency is high, artifacts appear. We have experimented on the degree of the dilution and CT-No to decide the optimum consistency of gastrografin for the diagnosis of pancreatic disease.
Statistical analysis of the results show the optimum dilution of gastrografin to be 1.5%.