腹部CT検査における内服させる造影剤濃度の研究
松島 紀志夫三村 誠一田原 誠司北山 卓一稲村 圭司三上 泰隆橋本 敬二平木 祥夫青野 要
著者情報
ジャーナル フリー

1985 年 97 巻 1-2 号 p. 47-53

詳細
抄録

A problem of Pancreatic CT scanning is the discrimination between the pancreas and the adjacent gastrointestinal tract. Generally we administer a dilution of gastrografin internally to make the discrimination. The degree of dilution has been decided by experience at each hospital.
When the consistency of the contrast medium is low in density, an enhancement effect cannot be expected, but when the consistency is high, artifacts appear. We have experimented on the degree of the dilution and CT-No to decide the optimum consistency of gastrografin for the diagnosis of pancreatic disease.
Statistical analysis of the results show the optimum dilution of gastrografin to be 1.5%.