Journal of Oleo Science
Online ISSN : 1347-3352
Print ISSN : 1345-8957
ISSN-L : 1345-8957
Oils and Fats
The Collaborative Study on the Enzymatic Analysis of Positional Distribution of Short- and Medium-chain Fatty Acids in Milk Fat Using Immobilized Candida antarctica Lipase B
Kazuaki YoshinagaShinichi SatoRyo SasakiMihoko AsadaRyuji HoriJun ImagiYosuke MiyazakiToshiharu NagaiKatsuyoshi SaitoTakashi SanoAkiko SasakiChiemi SatoYuki TsukaharaAtsushi YamashitaShimpei WatanabeYomi Watanabe
Author information
JOURNAL FREE ACCESS

2016 Volume 65 Issue 4 Pages 291-302

Details
Abstract

The positional distributions of fatty acids (FAs) in milk fat containing short- and medium-chain FAs were analyzed by sn-1(3)-selective transesterification of triacylglycerols (TAGs) with ethanol using immobilized Candida antarctica lipase B (CALB), in a collaborative study conducted by 10 laboratories. The mean C4:0, C6:0, and C8:0 FA contents, when analyzed as propyl esters (PEs) using gas chromatography (GC) with a DB-23 capillary column, were found to be 3.0, 2.0, and, 1.3 area%, respectively. Their reproducibility standard deviations were 0.33, 0.18, and 0.19, respectively. The mean C4:0, C6:0, and C8:0 contents at the sn-2 position were 0.3, 0.4, and 1.0 area%, respectively. Their reproducibility standard deviations were 0.17, 0.11, and 0.19, respectively. The reproducibility standard deviations of C4:0, C6:0, and C8:0 FAs at the sn-2 position were either the same as or smaller than those for milk fat, although the FA contents at the sn-2 position were smaller than those in the milk fat. Therefore, it was concluded that the CALB method for estimating the regiospecific distribution is applicable to TAGs containing short- and medium-chain FAs. When estimating the short-chain (SC) FA contents in fats and oils by GC, it is better to analyze SCFAs as PEs or butyl esters, and not as methyl esters, in order to prevent loss of SCFAs during the experimental procedure because of their volatility and water solubility. This study also revealed that the stationary phase of the GC capillary column affected the flame ionization detector (FID) response of SCFAs. The theoretical FID correction factor (MWFA / active carbon number / atomic weight of carbon) fitted well with the actual FID responses of C4:0-C12:0 FAs when they were analyzed as PEs using a DB-23 column; however, this was not the case when the GC analysis was performed using wax-type columns.

Content from these authors
© 2016 by Japan Oil Chemists' Society
Previous article Next article
feedback
Top