2016 Volume 28 Issue 3 Pages 722-724
[Purpose] The purpose of this study was to analyze test-retest reliability of an active range of motion test using a manual goniometer by unskilled examiners. [Subjects and Methods] Active range of motion was measured in 30 students attending U university (4 males, 26 females). Range of motion during flexion and extension of the shoulder and hip joints were measured using a manual goniometer. [Results] Flexion and extension of the shoulder joint (ICC=0.906 and ICC=0.808) and (ICC=0.946 and ICC=0. 955) of the hip joint showed excellent reliabilities. [Conclusion] The active range of motion test using a manual goniometer showed very high test-retest reliability in unskilled examiners. When examiners are aware of the method of the test, an objective assessment can be conducted.