Jinko Zoki
Online ISSN : 1883-6097
Print ISSN : 0300-0818
ISSN-L : 0300-0818
Study of Modified Human Sapenous Vein Homoglaft
Report On The Method Of Modification
S. UEMURA[in Japanese][in Japanese][in Japanese][in Japanese][in Japanese]
Author information
JOURNAL FREE ACCESS

1978 Volume 7 Issue 6 Pages 1011-1014

Details
Abstract
As a preparation of human saphenous vein homografts, proteolytis enzymatic digestion using Ficin was mandatory in order to increase the diameter of cadaveric veins.
The appropriate digestion time revealed to be 60-90min. However, the strength of the grafts was reduced in accordance with digestion pretreatment. 1.5% Glutar aldehyde was used for a tanning agent Patients with varicose vein will be good donors because of their increased size of veins Hence we conside to use the saphenous vein from varicose patients as well as from cadavers omitting.
Content from these authors
© The Japanese Society for Artificial Organs