日本細菌学雑誌
Online ISSN : 1882-4110
Print ISSN : 0021-4930
ISSN-L : 0021-4930
モルモット補体を利用したMycoplasma pneumoniaeの代謝阻止抗体測定法
岡崎 則男明間 鯉一郎滝沢 金次郎
著者情報
ジャーナル フリー

1990 年 45 巻 6 号 p. 931-936

詳細
抄録

Improvement of the fermentation-inhibition (FI) test for Mycoplasma pneumoniae was attempted. The sensitivity of detecting the FI antibody to M. pneumoniae in the homologous immune rabbit serum was notably elevated, when such FI medium containing gamma globuline-free horse serum and guinea-pig complement in substitution for unheated horse serum was used. The M. pneumoniae suspension was filtered to remove aggregates of the organisms and used as the antigen for this new FI test. In detection of the serum antibody of patients with M. pneumoniae infections, the new FI test showed much higher sensitivity than conventional FI test and strongly correlated (r=0.84) with high density particle agglutination test known to detect both IgG and IgM antibodies.

著者関連情報
© 日本細菌学会
前の記事 次の記事
feedback
Top