Japanese Journal of Clinical Chemistry
Online ISSN : 2187-4077
Print ISSN : 0370-5633
ISSN-L : 0370-5633
Assay Method and Normal Range of Guanase in Blood
SETSURO FUJIIKAZUHIRO IKENAKAHIROSHI YAMADASEIICHIRO YAMASAKI
Author information
JOURNAL FREE ACCESS

1983 Volume 12 Issue 3 Pages 208-213

Details
Abstract
1) Guanase activities in blood from 120 subjects were determined by measuring the radioactivity of 14C-uric acid derived from 14C-guanine.This method was able to determine the guanase activity less than 0.1 unit/l.
2) The normal range of guanase activity in serum was 0.2-0.8unit/l.
3) A correlation coefficient between the method which determine the ammonia released from 8-azaguanine by guanase colorimetrically and the method using radiolabelled substrate was 0.994, and thus it was shown that ammonia method is highly reliable in measuring the serum guanase activity of the normal range.
Content from these authors
© Japan Society of Clinical Chemistry