Volume 24 (1981) Issue 190 Pages 691-699
This paper presents the PVT-surface of water for temperatures from 273 to 1123 K up to a maximum pressure of 1 GPa given as a set of selected values. These selected values are derived from 6780 measured values by applying the method of error analysis previously proposed by the authors. In order to confirm the reliability of the method applied, the confidence intervals of the selected values as well as a result of the error analysis with respect to each set of measured values are closely examined. The validity of the selected values and their confidence intervals obtained as a result of this work are also confirmed both by examining the behavior of the proposed PVT-surface and comparing the selected values with the measured values.