The Proceedings of the Symposium on Environmental Engineering
Online ISSN : 2424-2969
2014.24
Session ID : 309
Conference information
309 Development of Liquid Sterilization Apparatus Using Gaseous Imploding Detonation
Minoru SUZUKIShun KONNO
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
The imploding detonation of a propane-oxygen mixture was used to generate underwater shock waves in a sample holder. We used the three kinds of experimental apparatuses whose the inner diameters of main combustion chamber are 60 mm, 150 mm, and 400 mm. The experimental results show that maximum pressure at the implosion center was 150 to 18000 times higher than the initial pressure. Although the maximum pressure in the exit of a sample holder changes with the sizes of experimental apparatus, pressure increase speed is almost constant. We found that the peak pressure in the end of a sample holder can be increased by expansion of the size of the main combustion chamber, and that we can perform scale-up and automatic operation of sterilization equipment.
Content from these authors
© 2014 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top