The software developed in this paper provides accurate, easy-to-use analysis technologies that can be used to analyze existing and/or new furnace tube for high temperature creep remaining life by using the life fraction rule. Evaluations include determination of the effect of general metal loss at both inner and outer side of the tube. The difference of remaining life evaluated by the safety factor method and standard deviation method is clarified.