日本機械学会関東支部総会講演会講演論文集
Online ISSN : 2424-2691
ISSN-L : 2424-2691
会議情報
1213 中性子ラジオグラフィ熱流動可視化・計測技術
呉田 昌俊秋本 肇
著者情報
会議録・要旨集 フリー

p. 417-418

詳細
抄録
In this manuscript, neutron radiography (NR) flow measurement techiques, which can measure the void fraction of boiling flow in narrow metal channels, were described. These techniques, high-frame-rate NR (NFR-NR) and NR3DCT, have been developed to study the void fraction and critical heat flux models. Measurement systems are consist of water-circulating loop with a NR test section, pre-heater, separator, condenser and DC power supply to generate the vapor, neutron-visible light converter, camera system which is automatically controlled by the computer and CT system in case of NR3DCT. NR images are processed on teh parallel super computer system. Exclusive image processing and visualizatio software calculates the void fraction and crops the data. Instantaneous void fraction can be measured by HFR-NR with time-resolution of 1ms. Spatial void fraction distribution can be measure by NR3DCT with spatial-resolution of 100μm. These two NR techniques make up the loss mutually, and we can obtain the spatial void fraction with high time resolution.
著者関連情報
© 2002 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top