Abstract
In the evaporation test of steam boilers, the quantity of heat absorbed by the furnace wall during the heating period will be very large compared with that after the thermal stationary state is arrived at. The author proposes to establish some rule on the preliminary firing period for such cases to limit the error of result within a certain range, and formulae to calculate it are given with an example.