The Proceedings of the Materials and Mechanics Conference
Online ISSN : 2424-2845
2011
Session ID : OS0511
Conference information
OS0511 Measuring magnetostriction of fatigued high strength steel
Kazuya KIYOFUJIYoshihito KUROSHIMA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
Fish eye failure that is unique fatigue fracture occurs in very long life region of high strength steel. However, mechanism of subsurface failure is unidentified. Measuring fish eye failure needs non-contact and the highly precise measurement. In this study, I examined using measurement by magnetostrictive effect and measuring magnetic property of high strength steel. As a result, high strength steel is magnetized in magnetic field. But fatigued high strength steel is not magnetized. This phenomenon is trapped magnetic wall movement by fatigue. Using measurement by magnetostrictive effect was difficult for high strength steel.
Content from these authors
© 2011 The Japan Society of Mechanical Engineers