動力・エネルギー技術の最前線講演論文集 : シンポジウム
Online ISSN : 2424-2950
2017.22
セッションID: A121
会議情報

熱劣化促進したケーブルの熱分解ガスのGC-MS分析
*松田 昭博矢吹 龍磨
著者情報
会議録・要旨集 フリー

詳細
抄録

In this study, accelerated thermal ageing tests of electrical cables for the nuclear power plants were carried out to evaluate effect of degradation of electrical cables on flammability. To evaluate flammability of electrical cables, the GC-MS (Gas Chromatography-Mass Spectrometry) method was applied. The Eco-material, polyethylene based electrical cables and the halogen free fire resistant cables were applied to this study. Temperature and period of accelerated thermal ageing tests of polyethylene based electrical cables were 90°C, 80°C, 70°C and 10, 20, 40 days, respectively. Temperature and period of accelerated thermal ageing tests of halogen free fire resistant cables were 100°C, 90°C, 80°C and 10, 20, 40 days, respectively. Evaluation results of GC-MS method of degraded sheath material of electrical cables were performed.

著者関連情報
© 2017 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top