サブクール沸騰領域を含む高温・高圧蒸発管の圧力損失評価手法の検証
*渡辺 悠太中山 嘉貴中拂 博之山田 明小澤 守
著者情報
会議録・要旨集 認証あり

詳細
抄録

To confirm the accuracy of predicting the pressure loss of an evaporator tube with a diameter used in boilers and under high heat flux conditions, the pressure loss in the tube was calculated using representative prediction equations and compared with experimental values. the test was conducted under the condition that water was used as the working fluid and the pressure was 8 -16 MPa. As a result, it was confirmed that the predicted value of pressure loss obtained by Thoms method agreed well with the experimental value even under the condition of high heat flux below CHF. On the other hand, to predict the friction loss under the condition of high heat flux and the regions from sub-cool to low steam quality, it is necessary to consider liquid temperature rise near the wall and subcooled flow boiling as previously reported. For subcooled flow boiling, it was confirmed that the prediction accuracy of friction loss was improved by using the simple calculation method of Sekoguchi.

著者関連情報
© 2022 一般社団法人 日本機械学会