スターリングサイクルシンポジウム講演論文集
Online ISSN : 2424-2926
会議情報
B02 タンデム型スターリング冷凍機の検討
関谷 弘志中崎 五夫中村 隆広小松原 健夫
著者情報
会議録・要旨集 フリー

p. 59-60

詳細
抄録
The authors had developed a Stirling cooler and cooling unit (single Stirling cooling unit). In addtion, A double Stirling cooling unit installing two Stirling coolers has been developed to aim at increasing in the cooling capacity of unit. This paper presents a tandem type Stirling cooler which is built up by connecting two Stirling coolers with coupling the crank shafts directly. The cooling unit with the tandem type Stirling cooler is superior to the double Stirling cooling unit, because motor input decreases and buffer tank is not necessary. So the tandem Stirling cooler could be very useful to make refrigeration systems higher efficiency, more compact and cost down.
著者関連情報
© 2002 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top