材料
Online ISSN : 1880-7488
Print ISSN : 0514-5163
ISSN-L : 0514-5163
減水剤を用いたコンクリートの減水と強度に関する研究
岡田 清西林 新蔵
著者情報
ジャーナル フリー

1967 年 16 巻 167 号 p. 642-649

詳細
抄録

To examine the effectiveness of water-reducing agents, typical one air-entraining agent, eight water-reducing admixtures and ten brands of normal portland cement now widely distributed throughout our country have been selected and used with some combinations.
Comparative tests have been performed of fresh concrete with respect to its water-reduction, bleeding and initial hardening, and of hardened concrete with respect to its strength gain, all these with the above-mentioned admixture, and, for contrast, of the control concrete having the same cement content of 300kg/m3 and consistency of 7.5cm without the critical admixture.
The results of the tests show that the good quality of water-reducing admixtures can reduce water requirement by 10 to 15 percent, bleeding per unit area by more than 30 percent and give higher compressive strength without any harmful effect on setting.

著者関連情報
© 日本材料学会