プラズマ・核融合学会誌
Print ISSN : 0918-7928
JT-60Uにおける第一壁コンディショニング—不純物および水素リサイクリングの制御
東島 智JT-60チーム
著者情報
ジャーナル フリー

1999 年 75 巻 11 号 p. 1297-1304

詳細
抄録

Wall conditioning can control impurity and hydrogen isotope. So various methods of wall conditioning have been adopted in JT-60U. After the vacuum vessel is closed and pumping system works, tokamak discharges can be obtained within a week. The conditioning can also make a good condition that recycled particles are so low as to correspond to injected NB particles. An equivalent QDT up to 1.25 can be transiently achieved in reversed shear plasmas because of both optimization of wall conditioning and improved confinement. Wall conditioning in JT-60U is discussed in this paper.

著者関連情報