The Journal of Toxicological Sciences
Online ISSN : 1880-3989
Print ISSN : 0388-1350
ISSN-L : 0388-1350
Original Article
hERG-activating compound ICA-105574 induces P-wave disappearance and cardiac arrest in isoflurane-anesthetized guinea pigs
Minato Ishida, Kazuharu Furutani, Keiichi Asakura, Satomi Kita
Author information
JOURNAL FREE ACCESS FULL-TEXT HTML
Supplementary material

2026 Volume 51 Issue 11 Pages 583-596

Details
Abstract

The human ether-à-go-go-related gene 1 (hERG1) encodes the pore subunit of a voltage-dependent K+ channel that mediates the rapid delayed-rectifier K+ current (IKr). Since patients with short QT syndrome (SQTS) carrying gain-of-function mutation in hERG1 have an elevated risk of lethal arrhythmias, small compounds that activate hERG/IKr channels may also pose a similar arrhythmic risk. To investigate the proarrhythmic risks associated with an hERG activator, we examined electrocardiogram (ECG) changes in an isoflurane-anesthetized guinea pig model upon the administration of ICA-105574, which has been reported to increase IKr in guinea pig myocytes. In the 10 mg/kg ICA-105574 group, ECG changes including pronounced QT shortening were observed. Meanwhile, all the animals treated with 30 mg/kg ICA-105574 exhibited cardiac arrest. The estimated unbound plasma concentration at the maximal point of action at 10 mg/kg of ICA-105574 was 0.54 µM, which was comparable to the half maximal effective concentration of hERG activation by ICA-105574 in the patch clamp study (0.49 µM). Furthermore, 0.15 mg/kg E-4031, a selective hERG inhibitor, prevented cardiac arrest induced by 30 mg/kg ICA-105574. These findings suggest that increased IKr induced by ICA-105574 causes cardiac arrest. Our data demonstrated that ICA-105574 has serious proarrhythmic risks, including cardiac arrest. For the development of ICA-105574 and other hERG-activating compounds as candidate therapeutic agents, it is imperative that proarrhythmic risks should be comprehensively evaluated before such agents are used in human patients.

INTRODUCTION

The human ether-à-go-go-related gene 1 (hERG1) K+ channel conducts the rapid delayed-rectifier K+ current (IKr), a component of repolarization in human cardiac myocytes (Sanguinetti and Tristani-Firouzi, 2006; Vandenberg et al., 2012). Both loss-of-function mutations in hERG1 and inhibition of hERG channels by compounds are known to induce QT prolongation (long QT syndrome [LQTS]) and associated potentially lethal ventricular tachycardia called Torsades de Pointes (Sanguinetti and Tristani-Firouzi, 2006; Schneider et al., 2026). Conversely, gain-of-function mutations in hERG1 are found in patients with short QT syndrome (SQTS), who also have an elevated risk of developing arrhythmias, which sometimes lead to sudden cardiac death (Brugada et al., 2004). This suggests that small compounds that increase IKr by activating hERG channels (El Harchi and Brincourt, 2022; Grunnet et al., 2008; Zhou et al., 2011) may pose a similar risk of life-threatening arrhythmia.

The rationale for administering a compound with hERG-activating activity to patients has been proposed: first, an hERG activator is suggested to relieve patients with LQTS with anticipation of antiarrhythmic action (Diness et al., 2008; Kemp et al., 2021; Kukavica et al., 2024; Meng et al., 2013; Shi et al., 2020), and second, any compound with an unintended hERG-activating effect (i.e., off-target effect on hERG) may be in clinical use to treat non-cardiovascular diseases. However, compared to the hERG-blocking effect of compounds, the proarrhythmic risks related to the hERG-activating effect have not been well tested.

3-nitro-N-(4-phenoxyphenyl) benzamide (ICA-105574) is an hERG-activating compound that increases hERG currents at the physiological membrane potentials (Gerlach et al., 2010). The primary mechanism by which ICA-105574 activates hERG channels is by eliminating inactivation gating at physiologically relevant voltages, because ICA-105574 (2 µM) shifts the midpoint of the voltage dependence of inactivation rightwardly from −86 to +96 mV (Gerlach et al., 2010). In addition to the effects on inactivation, ICA-105574 (3 µM) produced comparatively small hyperpolarizing shifts (up to 11 mV) in the voltage dependence of channel activation and a 2-fold slowing of channel deactivation (Gerlach et al., 2010). At the cellular level, it has been reported that ICA-105574 shortens the action potential duration dose-dependently in isolated guinea pig ventricular myocytes by increasing IKr (Gerlach et al., 2010). Moreover, Perry et al. tested ICA-105574 on human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs); it shortened the repolarization process in a concentration-dependent manner (Perry et al., 2020). Consistent with these findings, when administered to dogs and guinea pigs, ICA-105574 shortened the QT interval (Asayama et al., 2013; Kumawat et al., 2025). Therefore, ICA-105574 significantly affects the ventricular repolarization, presumably by an increase in IKr in ventricular myocytes. On the other hand, IKr is also recorded in other types of cardiac myocytes, such as sinus node (Matsuura et al., 2002; Verheijck et al., 1995) and nodal-type hiPSC-CMs (Ma et al., 2011). Perry et al. also demonstrated ICA-105574 suppressed automatic activities of hiPSC-CMs (Perry et al., 2020). These findings suggest that ICA-105574 affects sinus function, but this hypothesis has not been tested yet. Thorough in vivo studies are needed to understand how ICA-105574 affects the cardiac function.

Our overarching goal is to understand the possible proarrhythmic risks of the hERG activators when administered to human subjects. This study examined electrocardiogram (ECG) changes upon the administration of ICA-105574 in a well-established anesthetized guinea pig model that is used for preclinical safety testing in the pharmaceutical companies and basic studies at research institutes (Cao et al., 2019; Katagi et al., 2016; Ma et al., 2012; Morissette et al., 2013; Yao et al., 2008).

MATERIALS AND METHODS

Animals

This study was conducted in accordance with the Internal Regulations on Animal Experiments at Nippon Shinyaku Co., Ltd., which is based on the Law for the Humane Treatment and Management of Animals (Law No. 105, 1 October 1973, as amended on 19 June 2019). The experimental design followed the principle of reduction in laboratory animal use, aiming to minimize the number of animals while obtaining statistically interpretable results. For this reason, when an experimental group had already produced a definitive outcome, those data were used in common across the relevant analyses rather than repeating the experiment in additional animals.

Male Hartley guinea pigs (Japan SLC, Inc., Hamamatsu, Japan), aged 7-8 weeks, were utilized after 1-week acclimation. The weights of the animals ranged from 410 to 554 g on the day of the experiment.

Anesthesia and surgical procedures

Anesthesia was induced by inhalation of 4% isoflurane (Pfizer Inc., New York, USA). Tracheostomy was performed, followed by a transition to ventilation at a rate of 50-60 breaths per minute (SN-480-7, Sinano Manufacturing Co., Ltd., Tokyo, Japan). Isoflurane concentration was subsequently reduced to 2% and maintained until the end of the experiment. The body temperature of the animals was maintained at approximately 37°C throughout the experiment (Small Animal Warmer & Thermometer, BWT-100A, Bio Research Center Co., Ltd., Nagoya, Japan). Lead II surface ECGs were obtained from the fore and hind limbs. To administer vehicle or test compounds, a catheter was inserted into the left jugular vein. Additionally, when blood pressure measurement was conducted, another catheter was placed in the right carotid artery and connected to a transducer (MLT0699, ADInstruments, Dunedin, New Zealand). Similarly, when blood sampling was conducted, a catheter was placed in the right carotid artery. The animals were allowed a stabilization period of approximately 20 min from the completion of surgery to the start of experiment.

Dosing protocol

Each animal was administered the compounds or vehicle via continuous intravenous infusion for 10 min at a dose volume of 4 mL/kg (maximum dose volume) (KDS-100, KD Scientific Inc., Holliston, USA), after a 1-min baseline period. The sample size (n) for each vehicle- and compound-dosing group was four.

Drug solutions

ICA-105574 was purchased from AOBIOUS Inc. (Massachusetts, USA). E-4031 was purchased from Tocris Bioscience (Minneapolis, MN, USA). Each compound was initially dissolved in N,N-dimethylacetamide (NACALAI, Kyoto, Japan), and then diluted in polyethylene glycol 400 (NACALAI, Kyoto, Japan) and water for injection (Otsuka Pharmaceutical Factory, Tokushima, Japan) immediately before administration. The final composition of the vehicle was 10% N,N-dimethylacetamide, 70% polyethylene glycol 400, and 20% water. In a previous study that administered ICA-105574 to anesthetized dogs (Asayama et al., 2013), no ECG changes were observed at doses of 1 or 3 mg/kg, and ECG changes including QT shortening were observed at 10 mg/kg. Based on these findings, we set 10 mg/kg as the dose expected to induce pharmacological changes in this study. Furthermore, considering that toxicity assessments in drug development generally require doses exceeding the therapeutic dose (ICH, 2005), we also set 30 mg/kg, which was the maximal feasible dose, resulting from the maximal soluble concentration of ICA-105574 in the vehicle 7.5 mg/mL and the maximal volume of injection 4 mL/kg.

ECG and blood pressure recordings and analysis

The ECG and blood pressure data were acquired using PowerLab 8/35 (ADInstruments). The sampling frequency of ECG data was 1 kHz. Heart rate, PR, QT, JTpeak, Tpeak-Tend and QRS intervals were measured using Labchart 8 (ADInstruments) during the basal period, the 10-min dosing period, and the 20-min washout period. As QT and JTpeak intervals are known to correlate strongly with heart rate, these parameters were corrected using Bazett's formula (QTcB, JTpeakcB) and Van de Water's formula (QTcV, JTpeakcV), as described in a previous study using anesthetized guinea pigs (Hamlin et al., 2003; Morissette et al., 2015; Skinner et al., 2021). Meanwhile, Tpeak-Tend interval was not corrected for heart rate because it is known to not correlate well with heart rate (Hnatkova et al., 2017; Skinner et al., 2021). We calculated the Tpeak-Tend/QT ratio, a recognized ventricular proarrhythmic indicator (Gupta et al., 2008). ECG parameters were averaged from 10 beats for every minute. In the ICA-105574 30 mg/kg group, irregular PR intervals and bimodal or trimodal T waves were observed during the dosing period. The PR interval was not measured when irregular PR intervals occurred, and the JTpeak and Tpeak-Tend intervals were not measured when bimodal or trimodal T waves occurred. Furthermore, no ECG intervals could be measured after cardiac arrest.

Plasma drug concentration measurement

Apart from ECG experiments, plasma drug concentrations were measured following the administration of ICA-105574 at 10 mg/kg. Plasma drug concentrations after 30 mg/kg dosing that developed cardiac arrest could not be measured because severe hypotension occurred after administration, making blood collection impossible. Blood samples (~200 µL) were collected in tubes containing lithium heparin at 5-min intervals during the dosing period and at 10-min intervals during the washout period, and subsequently centrifuged (9,950 × g, 5 min) in a refrigerated centrifuge (Centrifuge 5427 R, Eppendorf, Hamburg, Germany) to obtain plasma. LC-MS/MS (LCMS-8050, Shimadzu, Kyoto, Japan) was used to determine the plasma drug concentrations. The protein-binding ratio of ICA-105574 in guinea pig plasma was determined using the equilibrium dialysis method (Wan and Rehngren, 2006) in conjunction with LC-MS/MS analysis (LCMS-8050, Shimadzu, Kyoto, Japan).

Statistical analysis

Data are presented as mean ± standard error of the mean (S.E.M.). Microsoft Excel 16 (Microsoft, Washington, USA) was used to calculate parameters, and Origin 2024 (OriginLab Corporation, Northampton, USA) was used to make figures. Comparison for ECG parameters of the ICA-105574 10 mg/kg and 30 mg/kg dose groups with the vehicle group at the same time points was conducted using one-way analysis of variance (ANOVA) followed by Dunnett’s test (Fig. 1). Multi-group comparisons for ECG parameters between ICA-105574 alone, E-4031 alone, the combined treatment, and the vehicle groups at the end of dosing were performed using one-way ANOVA followed by the Tukey-Kramer test (Table 1). Incidence of cardiac arrest was expressed as percentages and compared with Fisher’s exact test. The difference between the groups was considered statistically significant when the p-value was less than 0.05. The sample size (n) for each vehicle- and compound-dosing group was 4 at the start of administration. However, when the number of samples in either group was less than 3 due to cardiac arrest, irregular PR intervals, or the occurrence of bimodal or trimodal T waves, no statistical test was conducted for the time points. As described in the Results section, all animals treated with 30 mg/kg ICA-105574 developed cardiac arrest, and the incidence differed significantly from the vehicle group (Fisher's exact test). Because this outcome was unambiguous, the sample size was not increased further, in accordance with the principle of reduction in laboratory animal use. Stat Preclinica 4.1 (Takumi Information Technology, Tokyo, Japan) was used for statistical analysis.

Fig. 1

Changes in ECG parameters following ICA-105574 administration. Lead II surface ECGs were obtained from the fore and hind limbs. Doses of ICA-105574 were 10 and 30 mg/kg. (A) PR interval; (B) QRS duration; (C) QTcB; (D) QTcV; (E) JTpeakcB; (F) JTpeakcV; (G) Tpeak-to-Tend interval; (H) Tpeak-Tend/QT ratio; (I) Heart rate. The number of animals in each vehicle- and ICA-105574-dosing group was n = 4. However, owing to irregular PR intervals, bimodal or trimodal T waves, and cardiac arrest in all animals in the ICA-105574 30 mg/kg dose group, the PR interval was not measured after the time point of irregularity of the PR interval occurred in each animal. Additionally, JTpeakcB, JTpeakcV, and Tpeak-Tend were not measured after the time point of bimodal or trimodal T waves occurred, and no ECG intervals could be measured after cardiac arrest. The graph shows the mean and S.E.M. Black closed symbols indicate significant differences from the time-matched point values of the vehicle group at P < 0.05. No significant difference test was performed for the time points indicated as gray closed symbols as the number of samples in any of the groups was less than n = 3. QTcB and JTpeakcB represent QT interval and JTpeak interval corrected by the Bazett formula, while QTcV and JTpeakcV represent QT interval and JTpeak interval corrected by Van de Water's formula.

Table 1. ECG parameters at the end of dosing in each group.


RESULTS

ICA-105574 elevates the risk of ventricular arrhythmias in isoflurane-anesthetized guinea pigs

To evaluate the proarrhythmic risks of ICA-105574, 10 or 30 mg/kg of ICA-105574 was administered to isoflurane-anesthetized guinea pigs via 10 min of continuous intravenous infusion. ECGs were recorded during the basal period, the 10-min dosing period, and the 20-min washout period.

To investigate the effect of ICA-105574 on atrioventricular conduction and ventricular conduction, we analyzed the PR interval (Fig. 1A) and the QRS duration (Fig. 1B), respectively. In the 10 mg/kg ICA-105574 group, the PR interval prolonged by 23% compared to the vehicle group at the end of dosing (vehicle group, 62 ± 1 ms; 10 mg/kg ICA-105574 group, 76 ± 2 ms), whereas the QRS duration was not significantly different from that in the vehicle group at any time point (Fig. 1A and 1B, circles). In the 30 mg/kg ICA-105574 group, both the PR interval and the QRS duration were prolonged (Fig. 1A and 1B, triangles). Thus, ICA-105574 delayed atrioventricular conduction at both doses, whereas ventricular conduction delay (QRS prolongation) occurred only at 30 mg/kg.

To investigate the effect on the ventricular repolarization, QTcB and QTcV were analyzed. The QTcB and QTcV intervals were shortened in the ICA-105574 group compared to the vehicle group in a dose-dependent manner (Fig. 1C, 1D). In the 10 mg/kg ICA-105574 group, compared with the vehicle group at the end of dosing, QTcB was shortened by 24% (vehicle group, 297 ± 10 ms; 10 mg/kg ICA-105574 group, 227 ± 6 ms) and QTcV was shortened by 20% (vehicle group, 224 ± 6 ms; 10 mg/kg ICA-105574 group, 180 ± 4 ms). In the 30 mg/kg ICA-105574 group, QTcB was shortened by 52% from the vehicle group (vehicle group, 298 ± 8 ms; 30 mg/kg ICA-105574 group, 143 ± 5 ms) and QTcV was shortened by 39% (vehicle group, 225 ± 6 ms; 30 mg/kg ICA-105574 group, 137 ± 2 ms) at each maximum effect point.

To further evaluate the effects on the ventricular repolarization process, we analyzed the JTpeak interval (Fig. 1E and 1F, JTpeakcB and JTpeakcV), time to early repolarization, and Tpeak-Tend interval (Fig. 1G), time to late repolarization. Both JTpeakcB and JTpeakcV demonstrated dose-dependent shortening in the ICA-105574 treatment group compared to that in the vehicle group. Conversely, the Tpeak-Tend interval was significantly prolonged in both ICA-105574 treatment groups compared to that in the vehicle group. Therefore, ICA-105574 shortened and prolonged the duration of early and late repolarization, respectively. In addition, three of four animals in the 30 mg/kg ICA-105574 group exhibited bimodal or trimodal T waves 7–8 min after dosing initiation (Fig. S1).

The Tpeak-Tend/QT ratio is a sensitive indicator of risk for malignant ventricular arrhythmia because it reflects a final common substrate for arrhythmogenesis (Gupta et al., 2008). This indicator is elevated in patients with SQTS compared with healthy individuals (Gupta et al., 2008). Therefore, we calculated the Tpeak-Tend/QT ratio. The Tpeak-Tend/QT ratio was significantly increased in the ICA-105574 group compared to the vehicle group in a dose-dependent manner (Fig. 1H). These findings indicate that ICA-105574 elevates the risk of ventricular arrhythmias.

hERG activator ICA-105574 also induces P-wave disappearance and cardiac arrest in isoflurane-anesthetized guinea pigs

In addition to the aforementioned changes in ECG parameters, administering ICA-105574 to isoflurane-anesthetized guinea pigs resulted in cardiac arrest. In animals treated with 10 mg/kg ICA-105574 (n = 4), no mortality was observed (Fig. 2, circles, Fig. S2). In contrast, all animals treated with 30 mg/kg ICA-105574 (n = 4) experienced cardiac arrest between 8 and 13 min after dosing initiation (Fig. 2, triangles). The difference in the incidence of cardiac arrest between the vehicle and 30 mg/kg ICA-105574 groups was statistically significant (Fisher's exact test).

Fig. 2

Changes in the incidence of cardiac arrest following ICA-105574 administration. The administered doses of ICA-105574 were 10 mg/kg and 30 mg/kg. The sample size was n = 4 for each vehicle- and ICA-105574-dosing group. Data were compared using Fisher’s exact test. Black closed symbols indicate significant differences from the vehicle group at P < 0.05.

To understand the cardiovascular changes leading to cardiac arrest upon administration of 30 mg/kg ICA-105574, the heart rate, blood pressure, and ECG waveforms were analyzed. Fig. 3 shows the representative animal data (#1). Heart rate initially increased by 34% from basal (213 bpm) to the 6-min point (286 bpm), and then decreased continuously (9-min point, 113 bpm) until cardiac arrest at the 10-min point (Fig. 3A, left panel, averaged in Fig. 1I, triangles). Concurrently, the blood pressure continuously decreased from basal to cardiac arrest (basal, 24 mmHg; 9-min point, 13 mmHg) (Fig. 3A, right panel). In ECG, frequent disappearances of P wave were observed at the 9-min point (Fig. 3B, top right, Fig. S3), followed by cardiac arrest at the 10-min point (Fig. 3B, bottom). The other three animals (#2, #3 and #4) demonstrated similar alterations (Fig. S4). The disappearance of the P wave could arise from either of two mechanisms: loss of spontaneous activity in the sinus node, or impaired intra-atrial conduction (including atrial fibrillation). However, impaired intra-atrial conduction alone cannot account for the concurrent cardiac arrest, because subsidiary (escape) pacemakers in the atrioventricular junction or ventricle would have maintained ventricular automaticity. The simultaneous loss of P waves and cardiac arrest is therefore most probably consistent with a loss of spontaneous activity in the sinus node. Taken together, these findings suggest that ICA-105574 causes cardiac arrest, probably through suppression of sinus node automaticity.

Fig. 3

Changes in ECG waveform, heart rate, and mean blood pressure in a representative animal (#1) treated with ICA-105574 (30 mg/kg). Lead II surface ECGs were obtained from the fore and hind limbs. (A) Heart rate and mean blood pressure alterations from the initiation of 30 mg/kg ICA-105574 intravenous infusion to cardiac arrest. The left panel illustrates the heart rate change, whereas the right panel shows the mean blood pressure change. (B) ECG waveform alterations from the initiation of the intravenous infusion of 30 mg/kg ICA-105574 to cardiac arrest. The upper panel displays the ECG waveform prior to the commencement of dosing, the middle panel shows that at 9 min post-initiation of dosing, and the bottom panel illustrates that at 10 min after the initiation of dosing, immediately preceding cardiac arrest. The heart rate and mean blood pressure at these time points are also presented in the top right corner of each panel. HR denotes heart rate and is expressed in bpm, whereas MBP denotes mean blood pressure and is expressed in mmHg.

Estimated unbound plasma concentration measurement suggests increased IKr by ICA-105574 caused cardiac arrest

To investigate whether the aforementioned ECG changes and cardiac arrest are due to the IKr-activating effect of ICA-105574, we determined the estimated unbound plasma concentrations of ICA-105574 following administration to guinea pigs. We first planned to determine the estimated unbound plasma concentrations in animals after a dose of 30 mg/kg as well as 10 mg/kg. However, all animals treated with 30 mg/kg ICA-105574 exhibited cardiac arrest (Fig. 2); and severe hypotension occurred after administration, making blood collection impossible. Therefore, we decided that estimated unbound plasma concentrations should be determined only after administration of 10 mg/kg ICA-105574.

First, the total plasma drug concentrations (sum of protein-bound plus unbound fractions) were determined using LC-MS/MS. Second, the protein-binding ratio of ICA-105574 in guinea pig plasma was determined to be 99.1% by the equilibrium dialysis method, which was subsequently used to calculate the estimated unbound plasma concentration. Fig. 4 presents the time courses of estimated unbound plasma concentrations of ICA-105574 after dosing with 10 mg/kg. The mean estimated unbound plasma concentration 10-min after the initiation of dosing was 0.54 µM, which was comparable to the half maximal effective concentration (EC50) of hERG activation by ICA-105574 in the patch clamp study using human embryonic kidney (HEK) 293 cells (0.49 µM) (Gerlach et al., 2010). This finding suggests that ICA-105574 could increase IKr in animals during dosing of 10 mg/kg and that the administration of 30 mg/kg ICA-105574 further increased IKr.

Fig. 4

Estimated unbound plasma concentration of ICA-105574 in guinea pigs. The plots illustrate the temporal profile of the estimated unbound plasma concentration of ICA-105574 following administration of 10 mg/kg. The data are presented as the mean ± S.E.M. (n = 4).

Selective hERG blocker E-4031 prevents ICA-105574-induced cardiac arrest

To further verify that ICA-105574 caused cardiac arrest through its IKr-activating effect, we co-administered the selective hERG blocker E-4031 with 30 mg/kg ICA-105574. E-4031 was chosen because, even in the presence of ICA-105574, it has been reported to prolong the action potential of guinea pig ventricular muscle above baseline through IKr inhibition (Gerlach et al., 2010). To confirm that the dose actually inhibited IKr in vivo, we first administered E-4031 alone; at 0.15 mg/kg it delayed ventricular repolarization, prolonging QTcB by 51% relative to vehicle (Table 1). We therefore used 0.15 mg/kg E-4031 in the subsequent co-administration experiments.

Although cardiac arrest occurred in all animals treated with 30 mg/kg ICA-105574 alone, no cardiac arrest was observed in any animals co-administered 30 mg/kg ICA-105574 and 0.15 mg/kg E-4031 (Fig. 5A). The difference in the incidence of cardiac arrest between the 30 mg/kg ICA-105574 alone group and 30 mg/kg ICA-105574 plus 0.15 mg/kg E-4031 group was statistically significant (Fisher's exact test). This result supports the conclusion that increased IKr by ICA-105574 caused cardiac arrest. E-4031 certainly prevented P-wave disappearances caused by 30 mg/kg ICA-105574 (Fig. 5B). Representative ECG waveforms at 8-min after the initiation of dosing for vehicle, 30 mg/kg ICA-105574 alone, 30 mg/kg ICA-105574 with 0.15 mg/kg E-4031, and 0.15 mg/kg E-4031 alone are presented in Fig. 5B. Furthermore, proarrhythmic ventricular alterations in ECGs caused by 10 mg/kg ICA-105574 were reversed by co-administration of 0.15 mg/kg E-4031 (Table 1).

Fig. 5

Effect of 0.15 mg/kg E-4031 co-administration on cardiac arrest induced by 30 mg/kg ICA-105574. (A) Changes in the incidence of cardiac arrest following administration of vehicle, 30 mg/kg ICA-105574, co-administration of 30 mg/kg ICA-105574 and 0.15 mg/kg E-4031, or 0.15 mg/kg E-4031 alone. The data for the vehicle and 30 mg/kg ICA-105574 groups were replotted from the data in Fig. 2. Because all animals administered 30 mg/kg ICA-105574 developed cardiac arrest, this experiment was not repeated in order to minimize the number of animals used, in accordance with the principle of reduction in laboratory animal use. Data were compared using Fisher’s exact test. Black closed symbols indicate significant differences from the vehicle group at P < 0.05. Symbols with † indicate significant differences from the 30 mg/kg ICA-105574 alone group at P < 0.05. (B) Representative ECG recordings at 8 min post-administration of vehicle, 30 mg/kg ICA-105574, 30 mg/kg ICA-105574 with 0.15 mg/kg E-4031, and 0.15 mg/kg E-4031 alone. Lead II surface ECGs were obtained from the fore and hind limbs.

Taken together, we conclude that IKr-activating effect of ICA-105574 induces cardiac arrest and elevates the risk of ventricular arrhythmias.

DISCUSSION

This study assessed the proarrhythmic potential of ICA-105574 in isoflurane-anesthetized guinea pigs. ICA-105574 significantly altered ECG parameters at a dose of 10 mg/kg and induced cardiac arrest as well as P-wave disappearance at 30 mg/kg. Based on the findings of the plasma concentration measurements and co-administration experiments with a selective hERG inhibitor E-4031, the IKr-activating effect of ICA-105574 may be proarrhythmic, including through cardiac arrest. It should be emphasized that ICA-105574 produced two mechanistically distinct adverse outcomes: an elevated risk of ventricular tachyarrhythmia, inferred from repolarization-based surrogate markers (QT shortening, prolonged Tpeak-Tend, and an increased Tpeak-Tend/QT ratio) rather than from directly observed ventricular tachycardia or fibrillation; and a bradyarrhythmic event, namely cardiac arrest probably due to sinus arrest, which was the actual lethal event at 30 mg/kg. These two phenomena should not be conflated, although both are attributable to enhanced IKr.

IKr-activating compounds may impair the sinus node spontaneous activity

IKr has been most extensively characterized in Purkinje fibers and ventricular muscle, owing to its critical involvement in QT interval regulation and ventricular arrhythmogenesis through loss-of-function mutations or pharmacological blockade (Dumaine and Cordeiro, 2007; Fink et al., 2008; Finlayson et al., 2004; Sanguinetti and Tristani-Firouzi, 2006; Roden, 2008; Zeng et al., 1995). Although hERG1 expression and IKr are also detected in atrial and nodal tissues (Bertaso et al., 2002; Satoh, 2003), their functional significance in these regions has received comparatively less attention, partly because of their relatively minor contribution to action potential morphology compared with ventricular tissue (McPate et al., 2009; Odening et al., 2019; Ravens and Cerbai, 2008). In the present study, enhancement of IKr possibly altered nodal function and was accompanied by changes in the P wave (Fig. S3), suggesting a previously underappreciated capacity of IKr to modulate nodal and atrial electrophysiology. The nodal effects were most evident in the sinus rate and, at the higher dose, in sinus node automaticity. This observation is consistent with clinical reports of an increased risk of atrial fibrillation in patients carrying gain-of-function hERG1 mutations (Hong et al., 2005). Together, these results indicate that IKr plays a more complex role in cardiac electrophysiology than previously recognized, particularly in non-ventricular tissues.

During sinus rhythm, IKr has been proposed to contribute to the generation and maintenance of pacemaker function in conjunction with IKs, INa, ICa,L, If (Boyett et al., 2000; Irisawa et al., 1993; Matsuura et al., 2002). IKr may involve the sinus node action potential during two phases: (1) the repolarization process leading to the maximum diastolic potential and (2) the initiation of diastolic depolarization through the decay of outward potassium conductance (Verheijck et al., 1995). Selective inhibition of IKr by E-4031 in the sinus node resulted in a decrease in action potential firing frequency and cessation of spontaneous activity in studies using intact sinus nodes of the guinea pigs and rabbits (Matsuura et al., 2002; Verheijck et al., 1995). In contrast, the present study showed that ICA-105574 increased the heart rate after 10 mg/kg dosing, as well as at the early time points after 30 mg/kg dosing (Fig. 1I), an effect most likely attributable to enhanced IKr in the sinus node. This acceleration suggests that, when augmented, IKr contributes to sinus node pacemaking. This contribution probably occurs primarily by promoting diastolic depolarization, and possibly by hastening repolarization toward the maximum diastolic potential.

Whereas a modest increase in IKr accelerated the sinus rate, a larger increase had the opposite effect: at 30 mg/kg, ICA-105574 caused cessation of spontaneous activity, observed as P-wave disappearance in the ECG (Fig. 3B). To our knowledge, this is the first report of P-wave disappearance following in vivo administration of an hERG activator. We propose, as a hypothesis that requires direct electrophysiological testing in sinus node cells, that an excessive outward IKr stabilizes the membrane near the maximum diastolic potential and thereby suppresses the diastolic depolarization required to reach threshold, accounting for this biphasic, dose-dependent response. This interpretation is also consistent with the rescue experiment: at the dose used (0.15 mg/kg), E-4031 is expected to partially inhibit IKr, counterbalancing the excess IKr produced by ICA-105574 and restoring it toward the physiological range rather than abolishing the current, thereby preventing cardiac arrest (Fig. 5). Consistent with this notion, Perry et al. reported that ICA-105574 applied to hiPSC-CMs induced not only abbreviation of repolarization but also suppression of automatic activity (Perry et al., 2020). These findings may support the idea that the diastolic depolarization occurs partially through the decay of outward potassium conductance of IKr (Verheijck et al., 1995). Considering ICA-105574 effects on IKr channel activation, deactivation, as well as inactivation (Gerlach et al., 2010; Wu et al., 2014), it is conceivable that ICA-105574 could increase IKr around the maximal diastolic potential of sinus node cells. The cessation of spontaneous activity was not observed in the 10 mg/kg ICA-105574 group, where ECG changes including pronounced QT shortening were observed. As the contribution of IKr to action potential morphology is relatively minor in nodal tissue compared to ventricular tissue (Odening et al., 2019; McPate et al., 2009; Ravens and Cerbai, 2008), it is thought that the spontaneous activity ceased only in the 30 mg/kg ICA-105574 group due to the different sensitivity to increased IKr between cardiac myocytes. It should be noted, however, that our inference of a sinus-node-specific origin rests on surface ECG recordings and assumes that subsidiary pacemakers remain functional. Because IKr is expressed throughout the conduction system, an alternative possibility is that excessive IKr suppresses automaticity globally, with the sinus node failing earliest and most prominently because it is most sensitive to increased IKr. Distinguishing a sinus-node-specific effect from a more generalized suppression of automaticity will require direct recordings from nodal and subsidiary pacemaker cells. More broadly, systematic studies are warranted to fully elucidate the physiological impact of enhanced IKr function across different cardiac tissues, including the sinus node.

IKr-activating compounds have proarrhythmic potential associated with ventricular repolarization abbreviation

As sudden death due to ventricular fibrillation or ventricular tachycardia has frequently occurred in patients with the SQT1 subtype of SQTS, who carry gain-of-function mutations in hERG1 (Hancox et al., 2023), ventricular repolarization abbreviation due to increased IKr may elevate the proarrhythmic risk. The N588K mutation was the first genetic variant of SQT1 discovered in 2004 (Brugada et al., 2004), and the mechanism by which changes in IKr in that variant increase arrhythmic risk has been identified by a series of studies combining recombinant channel electrophysiology, in silico simulations, transgenic rabbit models and hiPSC-CMs models (Adeniran et al., 2011; Cordeiro et al., 2005; El-Battrawy et al., 2018; Hancox et al., 2020; Odening et al., 2019; Whittaker et al., 2017). N588K hERG1 mutation eliminates C-type inactivation (Cordeiro et al., 2005). In SQT1 patients with the N588K mutation, increased IKr markedly abbreviates action potential duration and effective refractory period of ventricular myocytes (Whittaker et al., 2017). In addition, transmural dispersion of repolarization increases, which would facilitate vulnerability to re-entry (Adeniran et al., 2011). Two- and three-dimensional simulations have also shown that the minimal substrate size required to sustain re-entry is decreased, resulting in an increase in lifespan for induced spiral or scroll waves (Adeniran et al., 2011).

Based on the proposed mechanism by which the N588K mutation in hERG1 increases the risk of arrhythmias (Hancox et al., 2020), it can still be postulated that IKr activation by the compound potentially increases proarrhythmic risks through a similar mechanism. The administration of ICA-105574 to guinea pigs in the present study resulted in prolongation of the Tpeak-Tend interval (Fig. 1G), an indicator of the transmural dispersion of repolarization (Xia et al., 2005), and increased the Tpeak-Tend/QT ratio (Fig. 1H), which is indicative of a final common substrate for arrhythmogenesis (Gupta et al., 2008). Consistent with this result, Qiu et al. assessed several markers of cardiac repolarization in Langendorff-perfused hearts isolated from guinea pigs and reported that ICA-105574 and another hERG activator NS-1643 increase the risk of ventricular arrhythmia (Qiu et al., 2019). These findings suggest that IKr activation by compounds may also potentially induce ventricular arrhythmias, including ventricular fibrillation and ventricular tachycardia.

The proarrhythmic risks of hERG activators

In this study, ICA-105574, an hERG activator, was administered to anesthetized guinea pigs to assess its proarrhythmic risks. At 10 mg/kg, where the estimated unbound plasma concentration at the time of administration was comparable to the EC50 for hERG activation, an increased risk of ventricular arrhythmias was suggested based on ECG changes, including QT shortening. Furthermore, at 30 mg/kg, the P-wave disappearance leading to cardiac arrest occurred in all animals (4 out of 4). Considering these results, the dose producing 100% lethality (30 mg/kg) was only 3-fold higher than the dose already associated with pharmacologically relevant hERG activation and ECG changes (10 mg/kg), indicating an extremely narrow safety margin between a pharmacologically active dose and a lethal dose. If ICA-105574 is developed as a pharmaceutical agent, this narrow safety margin would likely pose a serious challenge for its safe clinical use. In addition, we believe that the proarrhythmic risks of other hERG activators should also be carefully examined.

To date, more than 20 hERG activators have been identified, and categorized into four different types depending on their main reported mechanisms of action (El Harchi and Brincourt, 2022). ICA-105574 is categorized as type 2, which acts mainly through a rightward shift in the voltage dependence of inactivation (Gerlach et al., 2010). On the other hand, PD-118057, another hERG activator, is categorized as type 4, which increases the channel's open probability (Mao et al., 2013). Patel et al. have reported that application of PD-118057 to a canine ventricular wedge preparation abbreviated the QT interval. It increased the transmural dispersion of repolarization and the occurrence of polymorphic ventricular tachycardia when programmed electrical stimulation was applied to the epicardium (Patel and Antzelevitch, 2008). Previous studies have not focused on the differences between hERG activators with different molecular mechanisms. We hypothesize that hERG activators with different molecular mechanisms have different proarrhythmic risks. To investigate this hypothesis, we plan to conduct comparative experiments using anesthetized guinea pigs, as well as pharmacological experiments using isolated cardiomyocytes and heterologous expression systems, and simulation experiments using in silico models.

Limitations

First, in this study, the electrocardiographic effects of ICA-105574 were examined under isoflurane anesthesia, which is characterized by vagal dominance, rather than in the conscious state. The delayed rectifying K+ current in cardiomyocytes is divided into fast (IKr) and slow (IKs) activating components (Li et al., 1996). Since isoflurane inhibits IKs more potently than IKr (Suzuki et al., 2003), the action of ICA-105574 may be more potent under isoflurane anesthesia than under conscious conditions.

Secondly, species differences in the effects on ECG between humans and guinea pigs should be considered. As the relative contributions of IKr and other current components in each region of the heart differ between guinea pigs and humans (Ágoston et al., 2024; O’Hara and Rudy, 2012), IKr enhancement may result in different ECG parameter changes (such as heart rate and QT interval). These differences should be addressed in future studies.

Thirdly, the cardiac effects of ICA-105574 in this study were interpreted primarily in terms of its IKr-activating action, but its selectivity against other cardiac ion channels was not directly evaluated here. Some ECG findings, in particular the prolongation of the PR interval at 10 mg/kg and of the QRS duration at 30 mg/kg, are not readily explained by enhancement of the repolarizing IKr alone and could reflect either an effect of increased IKr on the conduction system or an off-target action on depolarizing currents. Although the prevention of cardiac arrest by the selective hERG blocker E-4031 indicates that the IKr-activating effect is central to the lethal phenotype, a contribution of off-target actions to the conduction changes cannot be excluded and warrants direct electrophysiological characterization.

Even with these limitations, the ECG changes observed in the isoflurane-anesthetized guinea pig model in this study are certainly possible in humans, and this possibility should be verified in the future by simulation experiments that model human ventricular myocytes and supraventricular tissues, including the sinus node.

Conclusion

The findings of this study, using an isoflurane-anesthetized guinea pig model, demonstrated that ICA-105574 poses proarrhythmic risks comprising both an increased risk of ventricular arrhythmias and, at higher concentrations, bradyarrhythmic cardiac arrest possibly due to sinus node suppression. These risks were attributed to the IKr-activating mechanism of ICA-105574. In the development of ICA-105574 and other IKr-activating compounds as pharmaceutical agents, it is imperative that proarrhythmic risks should be comprehensively evaluated before such agents are used in human patients.

ACKNOWLEDGMENTS

The authors thank Mr. Sasaki and Mr. Wang for the measurement of drug plasma concentrations.

Funding

This study was supported by the Scientific Research (C) 24K10045 (K.F.) from the Ministry of Education, Science, Sports and Culture of Japan, the Japan Society for the Promotion of Science.

Conflict of interest

The authors declare no competing interests.

Data availability

The data in this study are included in the article/supplementary materials. Contact the corresponding author directly to request the underlying data.

Author contributions

Conceptualization: Minato Ishida, Kazuharu Furutani, Keiichi Asakura, Satomi Kita

Funding acquisition: Kazuharu Furutani

Data acquisition, analysis and interpretation: Minato Ishida, Kazuharu Furutani, Keiichi Asakura, Satomi Kita

Writing - original draft: Minato Ishida, Kazuharu Furutani

Writing - review & editing: Minato Ishida, Kazuharu Furutani, Keiichi Asakura, Satomi Kita

Ethical approval and consent to participate

Not applicable.

Patient consent for publication

Not applicable.

REFERENCES
 
2026 Author(s)

This article is licensed under a Creative Commons [Attribution 4.0 International] license.
https://creativecommons.org/licenses/by/4.0/
feedback
Top