B119 オフアクシスディジタルホログラフィによる物体奥行き位置計測とその精度改善
中村 了村田 滋
著者情報
ジャーナル フリー

2006 年 26 巻 Supplement2 号 p. 117-120

詳細
抄録
This report compares the measurement accuracy of off-axis holographic technique with that of in-line holographic one, in digital holographic particle measurement. Off-axis holographic can separately reconstruct a real image a virtual image and offset to easily measure the object position in 3-D space with accuracy. It is seen in numerical performance tests that the object position can be more accurately measured with off-axis technique than in-line one, and the measurement error is affected by increasing object size and object number density.