風車タワーのL 型フランジにおける作用点修正係数の提案
飛永 育男石原 孟
著者情報
ジャーナル フリー

2016 年 40 巻 2 号 p. A_26-A_33

詳細
抄録

L-type flanges used for wind turbine towers need high bearing resistance when they install in storm and earthquake active areas. Petersen, Seidel, and RISO/DNV introduced methods for evaluation of L-type flange ultimate strength based on elastoplastic theory, however they didn’t consider the elastic deformation of flange and caused underestimation of the load acting on bolts. VDI2330, Petersen, and Seidel also showed the location of equivalent flange reaction force by using flange thickness direction bending moment equilibrium, but these methods are complicated. An action point correction factor of L-type flange is proposed to consider the effect of flange deformation and to expand the applicable range of flange dimension. The results show good agreement with those by the formula of Seidel at the ultimate condition by using load transmitting factor for L-type flange proposed in this paper.

著者関連情報
© 2016 日本風力エネルギー学会