59 巻 (1993) 557 号 p. 225-227
The mutual diffusion coefficient of the HCFC22-air system has been measured at 0-180°C and at atmospheric pressure by the Taylor method. The experimental uncertainty was estimated to be ±2%. The present results can be represented by the following equation : D=7. 47×10-10T1. 70, where D is the mutual diffusion coefficient in m2/s and T is the temperature in K. The mutual diffusion coefficient of the Ne-Ar system has also been measured at 30°C for checking the reliability of the present apparatus.