日本機械学会論文集 B編
Online ISSN : 1884-8346
Print ISSN : 0387-5016
ガンタイプバーナ近傍における保炎機構 : 乱れとガス濃度変動
池田 裕二河原 伸幸中島 健
著者情報
ジャーナル フリー

62 巻 (1996) 596 号 p. 1599-1607

詳細
PDFをダウンロード (936K) 発行機関連絡先
抄録

Three dimensional measurements of velocity and gas flux measurements of O2, CO2 flux near burner of oil furnace were demonstrated to show a flame holding mechanism and fluctuation characteristics. The use of convective flux in flame was not accurate but found to be applicable in whole combustion region in a furnace. Two pairs of recirculating flow region rotated in swirl direction due to the slit flow and its timescale was about 5-10 msec. The timescale of turbulence and CO, CO2 gas variation were compared in order to show the flame holding mechanism in a transparent evaporating region. The comparison results show that the timescale of turbulence and chemical species fluctuation were the same order.

著者関連情報
© 社団法人日本機械学会
前の記事 次の記事
feedback