口腔病学会雑誌
Online ISSN : 1884-5185
Print ISSN : 0300-9149
歯科用チタニウム及びジルコニウム合金の研究 (第7報)
チタニウムの大気中鑞接について
三浦 維四桜井 実
著者情報
ジャーナル フリー

1956 年 23 巻 2 号 p. 143-149

詳細
抄録

Brazing of titanium in air was studied, by using these alloys and fluxes which have been discussed in the previous report.
Table 1 shows the results of tensile tests under the combination of these alloys and fluxes.Most of them were ruptured at the brazed part by shear stress, however some were broken by tensite stress.
Alloys containing Ag 34-36%, Cu 17-19 %, Zn 5-15% and Cd 34-38% and fluxes I or IV were excellent as shown in Table 1.
The micro-structures of brazed specimens were also studied. Finally, these results stated above were compared with those of Dececco et al. The brazing processes which were studied in this paper were excellent in various points because of low brazing temperature utilized.

著者関連情報
© 口腔病学会
前の記事 次の記事