Continuous Cruciate Ligament Measurement Using Surface Mounted Transducers
Helen KambicAntonio ValdevitRichard JonesRichard ParkerJohn Bergfeld
著者情報
ジャーナル フリー

2002 年 43 巻 12 号 p. 3032-3035

詳細
抄録
Cruciate ligament and Achilles tendon graft elongation were studied using two methods of posterior cruciate ligament (PCL) reconstruction, a “Tibial Tunnel” and a “Tibial Inlay”. Under cyclic loading simulating an anterior drawer technique, elongations were recorded using an radially deflecting displacement transducer. The resulting periodic data was subjected to a Fourier analysis and comparisons between the anterior cruciate ligament and Achilles tendon graft elongations were examined for each surgical reconstruction. Spectral signatures revealed a more anatomic reconstruction resulted from the Tibial Inlay reconstruction as compared to the Tibial Tunnel reconstruction.
著者関連情報