MATERIALS TRANSACTIONS
Online ISSN : 1347-5320
Print ISSN : 1345-9678
ISSN-L : 1345-9678

This article has now been updated. Please use the final version.

Thickening of S-Phase and Sα-Phase of Various Stainless Steels Treated by Low Temperature Plasma Nitriding Using Screen
Shun HamashimaAkio Nishimoto
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: MT-M2022062

Details
Abstract

This study aimed to observe the thickening of the S-phase and Sα-phase of various stainless steels subjected to low-temperature direct current plasma nitriding using screen (S-DCPN). Austenitic stainless steel SUS304, ferritic stainless steel SUS430, and duplex stainless steel SUS329J4L were treated using two different screens for comparison, namely, a Ni screen and a steel plate cold commercial (SPCC) screen. Plasma nitriding was performed at 673 K for 300 min under a 75% N2 + 25% H2 atmosphere at 100 Pa pressure of the mixed gas. After nitriding treatment, the samples were examined using X-ray diffraction (XRD) and glow discharge optical emission spectrometry (GD-OES), and their cross-sectional microstructure and surface microstructure were examined using an electron probe micro analyzer (EPMA). Nitrided samples were also subjected to Vickers hardness and pitting corrosion tests. Examination of the SUS304 samples revealed thickening of its S-phase and higher surface hardness and pitting corrosion resistance when nitriding was done with the Ni screen. This was due to excess nitrogen diffusion into the sample due to presence of the Ni screen than with the SPCC screen. In the SUS430 samples, thickening of the Sα-phase was not be observed. When the Ni screen was used during nitriding, higher surface hardness and less pitting corrosion resistance of sample were observed, along with enhanced nitrogen diffusion than the SPCC screen was used. In the SUS329J4L samples, upon nitriding with Ni screen, thickening of the S-phase was observed and surface hardness and pitting corrosion resistance of the sample were higher, which was attributed to the enhanced nitrogen diffusion into the sample than when nitriding with the SPCC screen.

 

This Paper was Originally Published in Japanese in J. Japan Inst. Met. Mater. 86 (2022) 62–70.

Fig. 2 GD-OES nitrogen profiles of (a) SUS304, (b) SUS430 and (c) SUS329J4L samples treated by S-DCPN using Ni screen and SPCC screen. Fullsize Image
Content from these authors
© 2022 The Japan Institute of Metals and Materials
feedback