頸動脈エコーの最大内膜中膜複合体厚は,塞栓源となりうる大動脈複合粥腫病変の予測に有用である
徳山 承明清水 高弘伊佐早 健司高石 智清水 華奈子下邨 華菜萩原 悠太今井 健長谷川 泰弘
著者情報
ジャーナル フリー

2012 年 24 巻 2-3 号 p. 64-68

詳細
抄録

Background and purpose : Aortic plaque has been recognized as a potential source of embolism, for which diagnostic transesophageal echocardiography (TEE) is widely used in a clinical setting. TEE is not always performed in patients with definite embolic sources, including atrial fibrillation, because of the semi-invasive nature of the examination. Accordingly, the indications for TEE may vary among hospitals, resulting in underestimation of the clinical significance of aortogenic embolism. This study investigated the features predictive of aortic plaque on TEE, in order to establish systematic indications for TEE even in patients with an evident cardiogenic embolic source.
Methods : The subjects comprised 55 patients with acute ischemic stroke who were examined by TEE. Plaque 24 mm in diameter, or showing ulceration or mobile components, was diagnosed as complex plaque (CP). Multivariate logistic regression analyses and receiver operating characteristic (ROC) curve analysis were used to reveal factors predictive of the presence of CP.
Results : CP was demonstrated in 25 patients (45.5%). The maximum intima-media thickness (maxIMT) of the carotid arteries was significantly associated with CP (p = 0.005). The odds ratio and 95% confidence interval of the third tertile of maxIMT (1.8-6.1 mm) as a reference for the first tertile (0.6-0.8 mm) was 5.568 (1.131-27.410, p = 0.035). When the cutoff value of maxIMT revealed by TEE was set at 1.8 mm, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for diagnosis of CP were 52.0%, 80.0%, 50.0%, 6.7%, and 73%, respectively.
Conclusions : MaxIMT of > 1.8 mm for the carotid arteries determined by TEE was predictive of aortic plaque as a potential embolic source. A prospective clinical evaluation of carotid maxIMT determined by TEE, irrespective of other embolic sources, is warranted.