1982 年 31 巻 1 号 p. 61-66
We have treated 66 cases of trochanteric femoral fractures by using Compression Hip Screw. The incidence of local complication was no more than 5 percent, although the patients underwent a weight bearing from the early stage of post operation.
This method seemed to be very useful, which the patient can undergo a weigh bearing and leave the bed from the early stage of post operation.