大腿骨頸部外側骨折に対するチタン合金製 captured hip screw の治療成績の検討
中嶋 裕田口 厚伊藤 京衛山田 正幸宮崎 昌利朝長 久雄岩崎 勝郎池田 定倫西村 行政
著者情報
ジャーナル フリー

1989 年 37 巻 3 号 p. 1079-1082

詳細
抄録

The therapeutic results of using a titanium alloy captured hip screw in cases of external fractures of the femoral neck were studied. The subjects were eight males and 22 females, a total of 30 with an average age of 78.8. According to Evans' classification, the fractures were the stable type in 21 cases and the unstable type in nine cases. The average operating time was 56 minutes and the average hemorrhagic volume was 80ml which were not inferior to those of other methods of osteosynthesis. Loading of the hip was started in the 3rd week postoperatively on the average, and bone union was confirmed after 10.5 weeks on the average in all cases. One case of protrusion of the lag screw in the joint and one case of breaking of the fixation material were observed as postoperative complications, but these were both technical errors, and it was considered that good results can be obtained if care is taken concerning reduction of the eversion position of the fracture, correct insertion of the lag screw and accurate joining of the hip screw and plate.