耳鼻咽喉科展望
Online ISSN : 1883-6429
Print ISSN : 0386-9687
ISSN-L : 0386-9687
ショートモード型クリブ・オ・グラムの使用経験
浅野 公子小倉 脩二山本 賢之岡本 途也
著者情報
ジャーナル フリー

1985 年 28 巻 6 号 p. 581-589

詳細
抄録

Since 1980, we have been using the Crib-OGram at the Japanese Red Cross Medical Center to screen babies who were at risk for hearing loss.
In 1983 the shorter Crib-O-Gram (S-COG) without Interstimulus Intervals (ISI) was introduced. This report researches the comparison of results from the S-COG without ISI to results from the original Crid-O-Gram with NI (L-COG).
Average screening time with the S-COG was 37 minutes, and 1 hour 52 minutes with the L-COG. Screening scores were not significantly different between the two groups.
Second screening scores were significantly higher than the first one (P<0.01), which was conducted the previous day.
And when comparing the first and second screening scores, the S-COG's scores were significantly higher than those of the L-COG (P<0.01).

著者関連情報
© 耳鼻咽喉科展望会
前の記事 次の記事
feedback
Top