溶接学会論文集
Print ISSN : 0288-4771
アルミニウム管および銅管と各種心材との電磁圧接
マグネチック・インパルス溶接機による電磁圧接に関する研究(第1報)
穂苅 等佐藤 忠夫河内 邦夫武藤 章
著者情報
ジャーナル フリー

1997 年 15 巻 4 号 p. 615-622

詳細
抄録

In this study, aluminum and copper tubes (diameter : 10mm, thickness : 0.5mm) were welded to some kinds of bars by MIW (Magnetic Impulse Welding). The joints welded by MIW were evaluated by water tightness test, tension test and microscopic observation. The most suitable clearance between tubes and bars was 0.5mm for welding under the charged voltage of 14.0±2.5 kV, and it was not dependent on kinds of tubes and bars. Aluminum tubes could be welded with wider clearance than copper tubes, because the plastic deformation of aluminum tubes was easier than that of copper tubes. As bars were harder, tubes were welded better. Degreasing the welded interface had an effect on welding strength. The regular wavy pattern was observed on the welded interface. Microvickers hardness increased as approaching to the welded interface from the base metal of tubes and bars.

著者関連情報
© 一般社団法人 溶接学会