表面技術
Online ISSN : 1884-3409
Print ISSN : 0915-1869
ISSN-L : 0915-1869
技術論文
クロム化成皮膜中クロム(VI)の簡易高感度分析法
釜谷 美則柳 真三郎長島 珍男和久井 淳
著者情報
ジャーナル フリー

2008 年 59 巻 11 号 p. 749

詳細
抄録

The chromate conversion coatings treatment of aluminum was treated with 90 cm3 of boiling water for 5 min. The resultant solution was poured into solid phase extraction column (IBC Advanced Technologies Inc., Cr-02 type) and eluted with 2 cm3 of 3 mol/dm3 hydrochloric acid solution. The resultant solution was measured with Digital pack test for Cr (VI) (Kyoritsu Chemical-Check. Lab., Corp). The required time for total analytical procedure was faster than 10 min. The solid phase extraction column could be used repeatedly about 300 times or more. The minimum limit of determination of chromium (VI) was 0.004 mg/dm3.

著者関連情報
© 2008 一般社団法人 表面技術協会
前の記事 次の記事
feedback
Top