Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)
Online ISSN : 1882-1006
Print ISSN : 0015-6426
ISSN-L : 0015-6426
Comparative Study of Thermoluminescence Detection Methods for lrradiated Spices
Yoko KAWAMURAKana KOJIMATakiko SUGITATakashi YAMADAYukio SAITO
Author information
JOURNAL FREE ACCESS

1995 Volume 36 Issue 1 Pages 55-61_1

Details
Abstract
The thermoluminescence (TL) detection methods for irradiated spices were compared using spice samples obtained on the Japanese market, irradiated at doses of 1, 5, 10 and 30kGy and stored for 1 year before analysis. The TL intensities of irradiated spices were stable for 1 year after irradiation. Measurement with whole samples failed to identify irradiated samples. Minerals were separated from spices in sodium tungstate saturated solution and/or sodium polytungstate solution. The TL intensity of minerals which had undergone irradiation was significantly increased for all samples. However, the ranges of TL intensity of irradiated and unirradiated samples overlapped. Clear discrimination has been obtained between the TL ratios of irradiated and unirradiated spices by using normalized measurement with reirradiation. The detection limit in terms of irradiation dose is 1kGy even in a sample that has been irradiated 1 year prior to analysis. Normalization is the best technique currently available for thermoluminescence analysis to identify irradiated spices.
Content from these authors
© The Food Hygienic Society of Japan
Previous article Next article
feedback
Top