SICE Division Conference Program and Abstracts
3rd SICE Symposium on Industrial Application Systems
Conference information

Evaluation of characteristic Oval gear type flow meter with sonic nozzles
Hiroshi AsanoYoshiya TeraoSin-ichi Nakao
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 20

Details
Abstract
The oval gear type flow meter was taken up as a candidate of a working standard, and it was examined whether this had an enough performance as a working standard. As a result, when the Reynolds number larger than 1000, reproducibility of flow rate became ±0.17%. Therefore, oval gear meter uncertainly is 0.43% (coverage factor k=2). But it was able to make correction curve for flow rate and can correction. Finally therefore, uncertainty becomes 0.26% (coverage factor k=2).
Content from these authors
© 2002 SICE