Studies on Measuring Time Length of LAeq Concidering Noise Levels Distribution
Shouichi Tanaka
Author information
JOURNAL FREE ACCESS

1997 Volume 21 Issue 2 Pages 114-120

Details
Abstract

It is important to study measuring time length of LAeq in urban noise survey.
Environmental noise measurements were made to examine the relations between measuring time length and amount of deviation in LAeq, and the relation between LAeq and Lx.
The result show that
1) deviation in LAeq is not improved if the measurement is made over 10minites.
2) LAeq is accurately estimated from existing data of Lx with the aid of a certain equation.
It is concluded that the ordinary methods for L50 is applicable to LAeq measurements in environmental noise servay.