粉体工学会誌
Online ISSN : 1883-7239
Print ISSN : 0386-6157
ISSN-L : 0386-6157
論文
沈降管の沈降距離測定による粒子径分布解析
山本 哲也吉田 英人
著者情報
ジャーナル フリー

2019 年 56 巻 2 号 p. 66-73

詳細
抄録

Tangent line method and Twomey’s non-linear iteration method are applied to retrieve a particle size distribution from the sedimentation curve measured with a sedimentation distance in sedimentation tube. It is found that it is difficult to calculate the particle size distribution by the tangent line method using the sedimentation curve drawn from visual observation of the interface. On the other hand, the particle size distribution can be predicted numerically by Twomey method although the reliability is low. In order to improve the measurement accuracy, improved method to define the sedimentation interface using image analysis is investigated. Furthermore, introduction of correction term to Twomey method improves the reliability of the particle size distribution. As a results, this calculation method can be applied to measure particle size distribution not only for glass beads but also suspension concentrate of agricultural fungicide penthiopyrad.

著者関連情報
© 2019 一般社団法人粉体工学会