Spine Surgery and Related Research
Online ISSN : 2432-261X
ISSN-L : 2432-261X
ORIGINAL ARTICLE
Short Fixation Using Upward/Downward Penetrating Endplate Screws and Percutaneous Vertebral Augmentation for Unstable Osteoporotic Vertebral Fractures
Kengo FujiiYusuke SetojimaKaishi OgawaSayori LiToru FunayamaMasashi Yamazaki
Author information
JOURNAL OPEN ACCESS

2024 Volume 8 Issue 6 Pages 600-607

Details
Abstract

Introduction: Percutaneous vertebral augmentation techniques, such as balloon kyphoplasty (BKP) and vertebral body stenting (VBS), are commonly used for surgical intervention in osteoporotic vertebral fractures (OVFs). However, markedly unstable OVF cases require additional fixation procedures, prompting the exploration of combined percutaneous vertebral augmentation and posterior fixation. A novel surgical approach involving percutaneous vertebral augmentation with upward penetrating endplate screws (PES) and downward PES, complemented by a short fusion of one above one below, was developed. This study aimed to introduce and report the preliminary outcomes of this technique based on a retrospective analysis of 20 consecutive cases in the short and medium term.

Methods: Surgical indications are a vertebral wedge angle difference of 10° or more, vertebral pedicle fractures, posterior wall fractures, and diffuse low-signal changes exceeding 50% on T1-weighted magnetic resonance imaging. The procedure is reserved for highly unstable cases following a comprehensive health assessment. The surgical technique involves prone positioning, fluoroscopy-guided percutaneous vertebral augmentation, and the use of downward PES in the cranial vertebral body and upward PES for the caudal vertebral body by percutaneous technique. The fixation range is one above and one below.

Results: The case series of 20 patients, with an average follow-up period of 146.9 days, demonstrates a mean surgical time of 57 min and minimal complications. The advantages of the technique are as follows: ease of performance, minimal fixation range, and time efficiency. Risks, such as potential screw loosening and the need for prolonged follow-up, are acknowledged.

Discussion: The technique represents a promising surgical approach that balances the requirements of minimally invasive intervention and relatively robust initial fixation for elderly osteoporotic patients with unstable OVFs. While short- and medium-term results are favorable, long-term observations are needed to further assess its efficacy. This novel technique has a potential to be a valuable surgical option for unstable OVFs.

Fullsize Image
Content from these authors
© 2024 The Japanese Society for Spine Surgery and Related Research.

SSRR is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. Anyone may download, reuse, copy, reprint, or distribute articles published in the journal for not-for-profit purposes if they cite the original authors and source properly. If you remix, transform, or build upon the material, you may not distribute the modified material.
https://creativecommons.org/licenses/by-nc-nd/4.0/