日本原子力学会和文論文誌
Online ISSN : 2186-2931
Print ISSN : 1347-2879
ISSN-L : 1347-2879
論文
高温ガス炉水素電力コジェネレーションシステム用中間熱交換器の設計, (I)
伝熱管のスペック選定および1次応力評価
加藤 竜馬西原 哲夫國富 一彦
著者情報
ジャーナル フリー

2007 年 6 巻 2 号 p. 141-148

詳細
抄録

  Japan Atomic Energy Agency (JAEA) has been carrying out design studies of the Gas Turbine High Temperature Reactor 300 for Cogeneration (GTHTR300C). One of the key components in the GTHTR300C is an intermediate heat exchanger (IHX). The IHX for the GTHTR300C is rated 170MWt and designed on the basis of the shell & tube type IHX adopted in the High Temperature engineering Test Reactor (HTTR). As a conceptual design, we selected the heat exchanger tube size which is based on heat transfer calculation, designed conceptual structure, and evaluated the primary stress in design condition. By the results of this study, the technical feasibility of the large size shell & tube type IHX for the GTHTR300C was verified.

著者関連情報
© 2007 一般社団法人 日本原子力学会
前の記事 次の記事
feedback
Top